Experimental Investigation of Rotating Single-Hole Film Cooling Performance on Suction Side of a Turbine Blade

李国庆,邓宏武,肖俊
DOI: https://doi.org/10.13224/j.cnki.jasp.2010.04.016
2010-01-01
Abstract:Experimental investigations were carried out to study the rotating film cooling characteristics in a 1.5-stage turbine using stationary thermo liquid crystal method. The length of the test blade in chordwise and spanwise was 124.3mm and 99mm respectively with a 4 mm film hole in the middle span oriented 36° to the tangential of the suction side in stre-amwise. The mainflow was compressed and heated to bring the turbine to rotate with an in-let Reynolds number Re_g of 8 × 10~4. Air and CO_2 acted as coolant to achieve the coolant to mainflow density ratio of 1.03 and 1.57, respectively. Three rotation numbers of 2.092, 2.324 and 2.448 were considered. The blowing ratio varied from 0.3 to 3.0. Results show that on suction side there is an optimum blowing ratio to obtain the best film cooling effec-tiveness and coverage. Higher density ratio could generate larger film cooling coverage. Ro-tation is bad for film cooling effectiveness. Meanwhile, the film trajectory deflects centripe-tally a little due to the horseshoe vortex and rotating effect.