Experimental and Analytical Studies on Performance of Composite Frame under Column Loss

高山,郭兰慧,吴兆旗,张素梅
DOI: https://doi.org/10.14006/j.jzjgxb.2013.04.005
2013-01-01
Abstract:In order to study the behavior of composite frame under column loss,a 4-span,single-story steel-concrete frame was fabricated.The specimen was tested under middle-column loss.The experimental results show that,the progressive collapse of composite frame under middle column loss involves six stages consisting of elastic stage,elastic-plastic stage,arch stage,plastic stage,transient stage and catenary stage,in which the structure sustains and redistributes loads through the mechanism of hinge action and catenary action;composite beam could bridge over the remaining elements and assure the formation of catenary action while arch action could enhance the resistance of structure under column loss;the composite frame designed according to current design standard possesses good progressive collapse resistance under the failure of key column.Based on the test,a finite element model was developed,whose results were validated by comparing with the experimental results.This model provides an efficient modelling method on progressive collapse analysis of high-rise buildings.Based on the experimental phenomena and results,a new type of 'truss-spring' arch model was proposed to study the arch action in composite frame.The vertical displacement-load relationship formula and the vertical displacement-horizontal displacement relationship formula were derived.The accuracy of these two formulae is validated by comparing with the tests results.
What problem does this paper attempt to address?