Electrochemical Measurements Using Combination Microelectrode in Crevice Simulating Disbonded of Pipeline Coatings under Cathodic Protection

M. C. Yan,J. Q. Wang,E. H. Han,W. Ke
DOI: https://doi.org/10.1179/174327807x159934
IF: 1.971
2007-01-01
Corrosion Engineering Science and Technology
Abstract:The local potential and pH along a crevice simulating disbonded coating on pipelines were measured using microelectrodes.The effectiveness of cathodic protection(CP) in the local environment and the effects of applied cathodic potential,geometry of the crevice and solution conductivity were investigated.The results showed that the IR drop in the disbondment mainly occurred in the vicinity of the opening.The distance effectively protected by CP increased with the decreasing applied potential.However,hydrogen evolution had a reverse effect when an overprotection potential was applied.The additional effect of CP was shown to be the modification of the local environment,such as increase of pH and conductivity of solution,which was beneficial to corrosion controlling as well as direct polarization of the exposed steel at the holiday.
What problem does this paper attempt to address?