Immunological Assay For Carbohydrate Antigen 19-9 Using An Electrochemical Immunosensor And Antigen Immobilization In Titania Sol-Gel Matrix

D Du,F Yan,Sl Liu,Hx Ju
DOI: https://doi.org/10.1016/j.jim.2003.08.014
IF: 2.287
2003-01-01
Journal of Immunological Methods
Abstract:We describe a novel electrochemical immunosensor for carbohydrate antigen 19-9 (CA19-9) based on the immobilization of CA19-9 with titania sol-gel on a graphite electrode (GE) by vapor deposition. The CA19-9 membrane was characterized using scanning electron microscopy and proved to be chemically clean, porous and homogeneous. The incubation of the immunosensor in a solution containing horseradish peroxidase (HRP)-labeled CA19-9 antibody led to the binding of HRP-labeled antibody with the immobilized antigen. The immobilized HRP catalyzed the oxidation of catechol by H2O2 and this provided a competitive method for the measurement of serum CA 19-9. The response current decreased with increasing CA 19-9 concentration in the incubation solution. The effects of pH, amount of HRP-labeled antibody, incubation time and temperature were explored to provide optimum analytical performance. Under optimal conditions, the current decrease of the immunosensor was proportional to CA19-9 concentrations in the range of 3-20 U/ml with a detection limit of 2.68 U/ml at a current decrease of 10%. The detection of CA19-9 in two serum samples obtained from clinically diagnosed patients with pancreatic carcinoma showed acceptable accuracy. The proposed immunosensor provides a new promising tool for the clinical immunoassay of CA19-9. (C) 2003 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?