Quality Evaluation of Vancomycin Hydrochloride for Injection

YU Tong,ZHAO Rong-sheng,ZHOU Yong,ZHAI Suo-di
DOI: https://doi.org/10.3321/j.issn:1001-2494.2009.21.015
2009-01-01
Abstract:OBJECTIVE To evaluate the product quality of vancomycin hydrochloride for injection. METHODS The HPLC-UV method was established to determine the content of vancomycin B and related substances. The characteristics , pH, insoluble particulate matter and potency were evaluated at the same time. All the samples were evaluated based on National Drug Standards. RESULTS According to National Drug Standards, the results of the characteristics, pH, insoluble particulate matter and potency of all samples meet the standards, while the vancomycin B and related substances of 3 batches preparations of 2 manufactories were unqualified. All the samples meet the standard of JP15, USP30 and BP2007. CONCLUSION According to National Drug Standards, the products of manufactory A and C were all qualified, and the products of manufactory B and D were partially qualified.