Radiation dose and shielding effects for space radiation

Zhi ZENG,Junli LI,Xianghong JIA,Feng Xu,Zengxin HUANG
DOI: https://doi.org/10.16511/j.cnki.qhdxxb.2008.03.026
2008-01-01
Abstract:A Monte Carlo method was developed for dose assessment to analyze radiation dose rates and shielding effects for space radiation.The uniform,isotropic sampling algorithm was integrated with a voxel-based human phantom.The distributions of equivalent dose and effective dose per unit proton flux were calculated for three shielding thicknesses to analyze the effects of different shielding thicknesses.The peak of equivalent dose was between 100 and 200 MeV with a maximum effect dose at about 200 MeV.The contribution to the effective dose of secondary particles increased with increasing proton energy with heavy charge particle(HZE) increasing the fastest.The results show that the shielding for eyes and testicles should be thicker to reduce the radiation damager.