Experimental Analysis on Failure Mechanism of 500kv Transmission Tower under Ice Loading

XIE Qiang,SUN Li
DOI: https://doi.org/10.13336/j.1003-6520.hve.2010.12.033
2010-01-01
Abstract:In order to study the failure pattern and collapse mechanism of transmission tower under ice loading,a one-panel and a two-panel tower subassemblages of a typical 500kV transmission tower which were severely damaged during the ice disasters were fabricated.Both of two subassemblages were tested under simulated ice loading statically.The mechanical behavior,failure pattern,strain and deformation of substructures were investigated.The FEM software ANSYS was employed to analyze the behavior of two subassemblages by using shell elements.The experimental results showed that buckling of main leg was the basic failure mode of the structures,although the strains of the diagonal braces were relatively small.The out-of-plane deformations in the joints of the diagonal braces of the structures were considerable,and would significantly weaken the lateral constraining for main member of the structure.The effective length of the main angles would be increased.Meanwhile,the instability modes would exhibit obvious torsional-flexural buckling.The corresponding load-carrying capacity would be decreased notably.It can be concluded that restraining the out-of-plane deformation of the cross-bracings is one of the effective methods to enhance the ice load-carrying capacity of transmission tower.
What problem does this paper attempt to address?