Design and Performance Evaluation of Reference Capacitance Sensor Interface Circuit

XING Wen-qi,HU Hong-li,YAN Jie-bing
DOI: https://doi.org/10.3969/j.issn.1002-1841.2013.07.002
2013-01-01
Abstract:Gas-solid two-phase flow measurement technique based on capacitance sensors is considered to be the most promising gas-solid flow measurement technique.The capacitance sensor interface circuit is the key of capacitance sensor,and is important to the development and application of capacitive method gas-solid flow measurement technology.Tiny capacitance measurement's difficulty lies in the presence of stray capacitance and electromagnetic interference,and relaxation oscillator circuit can eliminate both ends of the capacitance' stray capacitance through the differential structure,it increases stability of circuit operation.Circuit can turn capacitance value into pulse width only with high and low level by the way of oscillation in order to transmit measurement result without interference.The reasonable use of the microprocessor can achieve high-precision measurement of the pulse width,thereby increasing the sensitivity and resolution of the measuring circuit as a whole.In order to be applied to the flow concentration measurement of gas-solid flow,the relaxation oscillator circuit with a reference capacitance was applied and its performance was tested.The results show that hysteresis error of the relaxation oscillation interface circuit with reference capacitance is 0.30%,nonlinearity error is 0.30% and repeatability error is 0.32%,and it is suitable for flow concentration measurement of gas-solid flow.
What problem does this paper attempt to address?