Determination of the Content of Vitamin A Palmitate and Its Related Substances by HPLC

LIU Ai,TANG Xiao-hai,XIE Yong-mei,HUO Xiao-fang,YANG Dan,HU Xiao,SONG Hang
2009-01-01
Abstract:OBJECTIVE:To establishment the method for the determination of content of vitamin A palmitate(VAP) and its related substances by HPLC. METHODS:The HPLC conditions were consisted of Phenomenex Luna C18 column with a mobile phase of a mixture of acetonitrile-isopropanol (90∶10) ,the detection wavelength of 328 nm,the column temperature of 30 ℃ and the flow rate of 1.0 mL·min-1. RESULTS:VAP was completely separated from impurities,the linearity range was 90~400 mg·L-1(r=0.999 2). The average recovery rate was 99.60% (RSD=1.32%). The average content of the related substances were lower than 2.53% . CONCLUSION: This accurate and reliable HPLC method is applicable for the quality control of VAP.
What problem does this paper attempt to address?