Changes of Intraocular Pressure in Patients Undergoing Laparoscopic Gynecologic Operations

蒋忠,马正良,董媛媛
2009-01-01
Abstract:Objective To observe the changes of intraocular pressure(IOP)during laparoscopiy(LC)gynecologic operations.Methods The IOP,SBP,DBP and HR in 16 patients undergoing LC gynecologic operation were recorded at 5 min after anesthesia induction and from 5 min of LC to 15 min after completion.Results No statistical changes of SBP,DBP and HR were found perioperatively.The IOP under head down operative posotion began increasing during artificial pneumoperitoneum,which reached peak level at 5 min before ending pneumoperitoneum.The IOP descented gradually under supin position after completion of pneumoperitoneum.Conclusion The IOP is increased in patients undergoing laparoscopic gynecologic operation with artificial pneumoperitoneum,which could be harmful to vision.Attention shoud be paid to the protection of the eyes.
What problem does this paper attempt to address?