Study on UF for the Separation and Purification of Hypocholesterolemic Peptides from Whey Protein Hydrolyzate

Zhang Jin-feng,Leng You-bin,Li Xiao-dong,Jiang Shi-long,Wang Yan,Wang Yang
2013-01-01
Abstract:Ultrafiltration membranes with different molecular weight were used to initially separating the hypocholesterolemic peptides of whey protein hydrolyzate.Detect the hydrolysates HMG reductase inhibitory activity before and after ultrafiltration.Determine the process parameters of the ultrafiltration.The result showed that 5 kDa ultrafiltration membrane can more significantly improve their inhibitory activity,the optimized separation conditions of ultra filtration was as follows: the temperature 25 ℃,pressure 0.20 MPa,time 30 min and pH 6.5,and HMG-CoA reductase inhibitory activity can be achieved more than 20%.