Removal Rules of COD and NH4+-N in Secondary Domestic Sewage by UBAF

闫立龙,张颖,任源,都昌杰
DOI: https://doi.org/10.3969/j.issn.1005-9369.2009.01.010
2009-01-01
Abstract:Up-flow Biological Aeration Filtration(UBAF) was used to treat simulated secondary domestic sewage, removal rules of COD and NH4+-N by UBAF were studied, and the effect of organic load, hydraulic load and media height on removal efficiency of the two parameters was investigated. The results showed that a stable water quality of effluent was obtained, and average removal efficiencies of COD and NH4+-N were 71.88% and 75.28%, respectively. The treatment efficiency of pollutants was influenced evidently by organic load and hydraulic load, which obtained optimal values of 4.67 kg·m-3·d-1 and 7 m·h-1 respectively. There existed different kinds of bacteria which changed along the different layers of UBAF, with mainly heterotrophic bacteria in influent part and nitrifying bacteria in effluent part. Distribution of bacteria on different layers weakened with the increment of organic load.
What problem does this paper attempt to address?