Intrascleral Knotless Zigzag Suture Fixation of Four-Haptic Hydrophilic Acrylic Foldable IOL: Clinical Outcomes
Nisa Silva,André Ferreira,Natália Ferreira,Bernardete Pessoa,Angelina Meireles
DOI: https://doi.org/10.2147/OPTH.S340039
2022-01-06
Clinical Ophthalmology
Abstract:Nisa Silva, 1, &ast André Ferreira, 1, 2, &ast Natália Ferreira, 1 Bernardete Pessoa, 1, 3 Angelina Meireles 1, 3 1 Department of Ophthalmology, Centro Hospitalar Universitário do Porto, Porto, 4099-001, Portugal; 2 Unit of Anatomy, Department of Biomedicine, Faculty of Medicine of University of Porto, Porto, 4200-319, Portugal; 3 Department of Ophthalmology, Instituto de Ciências Biomédicas Abel Salazar, University of Porto, Porto, 4050-313, Portugal &astThese authors contributed equally to this work Correspondence: Nisa Silva Department of Ophthalmology, Centro Hospitalar Universitário do Porto, Largo do Prof. Abel Salazar, Porto, 4099-001, Portugal Tel +351 22 207 7500 Email Background: The main options for intraocular lens (IOL) placement without capsular bag support and/or zonular weakness are iris-fixated IOL and scleral-fixated IOL (SFIOL). Purpose: To describe the surgical technique and the outcomes of intrascleral knotless zigzag suture fixation of Akreos AO60 foldable IOL. Methods: Retrospective cohort study of consecutive cases. Results: Ninety-nine eyes of 92 patients were retrospectively studied. The mean age was 72.1± 15.2 years (range 18– 94), and the median follow-up duration was 19.5 months (range 3– 81). The best-corrected visual acuity improved from a mean±SD of 1.34± 0.70 logarithm of the minimum angle of resolution (logMAR) units at baseline to 0.49± 0.56 logMAR at the end of follow-up (p< 0.001). The mean±SD final SE was − 1.24± 1.82 diopters. The mean±SD prediction error was − 0.51± 1.16 diopters. The overall perioperative complications rate was 44.4% (n=44). The rate of complications requiring invasive treatment was 19.2% (n=19). The most common perioperative complications were ocular hypertension (OHT, 20.2%, n=20), and cystoid macular edema (CME, 15.2%, n=15). The rate of IOL dislocation was 7% (n=7). Conclusion: This knotless technique avoids the risks of haptics fixation but is more prone to IOL dislocation in cases of suture deterioration. Past ophthalmic history needs to be carefully considered in candidates who underwent SFIOL implantation. Keywords: intraocular lens, scleral fixation, knotless, cataract, lens luxation Phacoemulsification with intraocular lens (IOL) placement in the capsular bag is the gold standard for cataract surgery with adequate capsular support. When an adequate capsule support is absent and/or zonules are weak or absence, the main options are iris-fixated IOL (IFIOL) and scleral-fixated IOL (SFIOL), with the expectancy of similar outcomes. 1–3 Some surgeons would rather to implant a SFIOL to ensure a more physiologic position and to avoid the risk of corneal decompensation. 4,5 However, the scleral fixation is technically challenging and not devoid of risks. Over the last years, many surgical techniques have been described, and novel IOL designs have increased the armamentarium of SFIOLs. The method of fixating an IOL in the sclera may use sutures or not. The sutured techniques have been modified to incorporate scleral flaps or pockets to prevent the conjunctival erosion provoked by exposed knots. 4 Alternatively, the knot can be avoided by running the suture through the partial thickness of the sclera in a zigzag pattern. 6 Using thicker or other types of threads has been further suggested to reduce suture breakage and lens dislocation or tilt. 7 The sutureless techniques using fibrin glue 8 or scleral tunnels 5,9–12 have gained popularity recently. While novel techniques have been introduced, IOL designs have also evolved. CZ70BD IOL 13 (Alcon, Fort Worth, Texas), for example, includes eyelets to prevent the suture slippage and subsequent lens dislocation. Akreos AO60 14 (Bausch & Lomb, Rochester, New York) is a foldable IOL with eyelets, and its off-label use as a SFIOL has been reported. FIL SSF Carlevale IOL 15 (Soleko, Italy) was specifically engineered for scleral fixation without sutures. In our center, intrascleral knotless zigzag suture fixation of Akreos AO60 foldable IOL has been adopted as the standard surgery for eyes with poor capsular support. The present study aims to describe the surgical technique, functional outcomes and perioperative complications of intrascleral knotless zigzag suture fixation of Akreos AO60 foldable IOL. This is a retrospective, observational, single-center study of consecutive eyes submitted to scleral fixation of AkreosAO60 foldable IOL using the knotless zigzag technique at Centro Hospitalar Universitário do Porto (CHUPorto), a tertiary ce -Abstract Truncated-