Y-stent-assisted coil embolization for wide-necked aneurysms located at basilar artery tip: its technical points

XU Hao-wen,LI Ming-hua,GUAN Sheng,WANG Wu,SONG Bo,GU Bin-xian
DOI: https://doi.org/10.3969/j.issn.1008-794x.2011.05.005
2011-01-01
Abstract:Objective To explore the technical points of Y-stent-assisted coil embolization for wide-necked aneurysms located at basilar artery tip and to discuss the suitable management for refractory cases.Methods During the period from Jan.2008 to Jan.2011,Y-stent-assisted coil embolization was carried out in six patients with ruptured wide-necked aneurysm located at basilar artery tip,the clinical data were retrospectively analyzed.Before the procedure,CTA,MRA or DSA were performed in all patients to confirm the diagnosis.The diameter of the aneurysms was > 10 mm(n = 1),5 ~ 10 mm(n = 4)and 3 ~ 5 mm (n = 1).The complications were observed and the clinical results were analyzed.Results A total of 11 stents were used in six patients,including Neuroform stent(n = 9)and Enterprise stent(n = 2).Total or subtotal embolization of the aneurysm was achieved in all patients.Stent-assisted coiling technique was smoothly accomplished in four cases.Stent migration occurred in two cases during the procedure.No severe perioperative complications occurred in all six cases.Conclusion Standard and proficient manipulation together with the use of appropriate and suitable stent can greatly decrease the occurrence of complications after Y-stent-assisted coil embolization for wide-necked aneurysms located at basilar artery tip.
What problem does this paper attempt to address?