Determination of Loureirin A in Solid Lipid Nanoparticles Encapsulating Resina Draconis by HPLC

叶菲,楼雪芳,杜永忠
DOI: https://doi.org/10.13748/j.cnki.issn1007-7693.2013.01.011
2013-01-01
Abstract:OBJECTIVE To establish an HPLC method for determination of loureirin A content in solid lipid nanoparticles(SLN) of Resina Draconis.METHODS A DiamonsilTM C18(200 mm×4.6 mm,5 μm) column was used for the determination of loureirin A with mobile phase of acetonitrile-1% acetic acid solution(38∶62).The flow rate was 1.3 mL·min 1,the detection wavelength was set at 260 nm,and the column temperature was 40 ℃.RESULTS The linear range of 1oureirin A was 0.135 5.4 μg·mL 1,Y=33.694X+1.589 8(r=0.999 9).The RSDs of within-day were 2.70%,2.36%,1.48%,and the RSDs of between-day were 2.70%,2.61%,1.97% in the high-,middle-,and low-dose Resina Draconis loaded SLN.The average recovery was 99.2%(RSD 3.9%),and the average drug encapsulation efficiency was 89.59%.CONCLUSION The method is simple and reliable for the determination of loureirin A in Resina Draconis loaded SLN.