Comparative Study Between Dual-Wire Focused Force Angioplasty and Balloon Angioplasty for Treating Small Coronary Artery Lesions

ZHANG Lin-lin,ZHOU Yu-jie,ZHAO Ying-xin,LIU Yu-yang,SHI Dong-mei,LIANG Jing,YANG Li-xia,WANG Jian-long
DOI: https://doi.org/10.3969/j.issn.1000-3614.2013.01.005
2013-01-01
Abstract:Objective:To compare the immediate and long term effect between dual-wire focused force angioplasty and balloon angiopla-sty for treating small coronary artery lesions. Methods:A total of 150 consecutive patients with coronary angiography(CAG)confirmed lesions in small coronary arteries in diameter≤2.5 mm were randomly assigned into 2 groups.Group A,the patients received dual-wire focused force angioplasty and Group B,the patients had balloon angioplasty group.n=75 in each group.Follow-up CAG performed 6~9 months after the treatment to observe the vessel restenosis and major adverse cardiac event(MACE)related to small vessel lesions. Results:Procedural success rate in Group A and Group B was 97.3% vs.86.7%,P=0.015,the procedural complication was 1.3% vs.6.7%,P=0.032.The follow-up CAG indicated that the vessel restenosis in Group A and Group B was 12.7% vs.31.8%,P< 0.05,the occurrence of MACE at 12 months was 5.4% vs.18.5%,P=0.035. Conclusion:Compared with balloon angioplasty,dual-wire focused force angioplasty could reduce the procedural complications and increase the success rate for small coronary artery disease intervention;it also had less retenosis and MACE within 1 year of treatment.