HVDC Partial Discharge Detecting Instrument Used for Storage Capacitors
QU Yan-ning,WU Guang-ning,ZHANG Xue-qin,WANG Peng
DOI: https://doi.org/10.3969/j.issn.1003-6520.2007.08.031
2007-01-01
Abstract:High voltage(HV) storage capacitor is widely used in pulse power equipments.When it works,it is charged under DC source in a long time and discharges at a high voltage and large current pulse in a very short time.This pulse is the main reason to induce the capacitor aging.In order to test the performance of the capacitor,a suit of HVDC partial discharge(PD) detecting instrument was developed,the optimum bandwidth of which is about 64~257kHz based on the parameters of the defects,and the results of the preliminary experiments were gained.In order to increase the sensitivity of measurement system for large capacitance,the RLC balanced detection circuit was used to pick-up the DC PD.After being amplified by a narrowband,gain-stable differential amplifier and filtered by a band-pass filter,these PD signals were sent to the sampling software by an acquisition card.Through the experiments,the magnitudes of PD over time in different capacitors were got.After statistic analyzed by application of the Delta(t) method,the Qmax-Δt,mean-Δt,n-Δt and n-Q curves related to DC PD were extracted.For the different characters of the statistic graphs,all kinds of defects can be clearly distinguished from these curves and the causes of the differences between these curves are preliminary analyzed.These results would be further used to the statistic analysis of DC PD,which were the base to recognize the PD patterns and to determine fault types and aging degree.In order to test the performance of a capacitor,a suit of HVDC partial discharge(PD) detecting instrument was developed,the optimum bandwidth of which is about 64~257kHz based on the parameters of the defects,and the results of the preliminary experiments were gained.In order to increase the sensitivity of measurement system for large capacitance,the RLC balanced detection circuit was used to pick-up the DC PD.After being amplified by a narrowband,gain-stable differential amplifier and filtered by a band-pass filter,these PD signals were sent to the sampling software by an acquisition card.Through the experiments,the magnitudes of PD over time in different capacitors were abtained.After statistically analyzing the application of the Delta(t) method,the Qmax-Δt,-Δt,n-Δt and n-Q curves related to DC PD were extracted.For the different characters of the statistic graphs,all kinds of defects can be clearly distinguished from these curves and the causes of the differences between these curves are preliminary analyzed.These results would be further used to the statistic analysis of DC PD,which were the base to recognize the PD patterns and to determine fault types and aging degree.