Safety and efficacy of transcatheter occlusion for the treatment of ruptured sinus of aortic aneurysm

GUAN Lihua,XIE Diyang,ZHOU Daxin,CHEN Dandan,ZHANG Lei,PAN Wenzhi,GE Junbo
2012-01-01
Abstract:Objective To evaluate the immediate and mid-term outcome of transcatheter interventional treatment for ruptured sinus of aorta (RSA). Methods Twelve RSA patients (8 males and 4 females, aged from 16 to 64 years with an average age of 38.9±13.2 years) were enrolled this study. Patent ductus arteriosus (PDA) or ventricular septal defect (VSD) occluders was used for transcatheter closure. All the patients were followed up for 6 months. Results Aortic angiography showed that the RSA was (9.9±2.9) mm at its narrowest end. Eleven patients were successfully treated. PDA occluder (2-4 mm larger than the narrowest end) was applied in 9 patients and VSD occluder (3-5 mm larger than the narrowest end) was used in 2 patients. Neither residual shunt (except in one case) nor severe aortic regurgitation was found by transthoracic echocardiography. There were no device embolism, infective endocarditis or myocardial ischemia in any of the patients. Both the length of stay and medical costs of these patients were less than those who received surgery during the same period. Conclusion Transcatheter closure with PDA occluder or VSD occluder is feasible and effective.