[LC-MS/MS Analysis of Determination of Strychnine and Brucine in Formaldehyde Fixed Tissue].

Lan-fen Zhan,Ming-dong Liu,You-yi Yan,Yi Ye,Wei Wang,Zhi-hui Wang,Jun-hong Zhao,Lin-chuan Liao
DOI: https://doi.org/10.3969/j.issn.1004-5619.2012.05.006
2012-01-01
Abstract:OBJECTIVE:To establish a method for determination of strychnine and brucine in formaldehyde fixed tissue by LC-MS/MS analysis.METHODS:The samples were pretreated with solid phase extraction using SCX cartridges and separated on SB-C18 column with mobile phase 0.1% formic acid : 0.1% formic acid-acetonitrile (75:25). Electrospray ionization (ESI) source was utilized and operated in positive ion mode. Multiple reactions monitoring (MRM) mode was applied. External standard method was applied for quantitation.RESULTS:The chromatographic separation of strychnine and brucine in formaldehyde fixed nephritic and hepatic tissues resulted successfully. The standard curve was linear in the range of 0.002-2.0 microg/g for strychnine and brucine in formaldehyde fixed tissues, and the correlation coefficient was more than 0.996. The limits of detection (LOD) of strychnine and brucine in nephritic tissues were 0.06ng/g and 0.03 ng/g, respectively. The LOD of both chemicals were 0.3 ng/g in hepatic tissues. The extraction recovery rate was more than 74.5%. The precision of intra-day and inter-day were both less than 8.2%.CONCLUSION:Strychnine and brucine can be sensitive to be determined in formaldehyde fixed tissue by LC-MS/MS analysis. It can be applied in the forensic toxicological analysis.
What problem does this paper attempt to address?