Development of Ultrasonic Flow-detecting System based on DSP and CPLD

Luo Zhimeng,Zhou Jianzhong,Huang Zhiwei,Xu Jianhong,He Hui
DOI: https://doi.org/10.3969/j.issn.0559-9342.2008.05.005
2008-01-01
Abstract:To compensate the poor data handling ability,low accuracy and reliability of the traditional ultrasonic flowmeter,the IUFS(intelligent ultrasonic flow-detecting system) based on DSP and CPLD is designed and developed,which uses frequency-difference principle and sing-around method to measure the variables such as flow,volume and so on.The IUFS utilizes DSP(Digital Signal Processing) chip TMS320F2812 as the keycontroller,CPLD(Complicated Programmed Logic Device) chip EPM240 as the logic controller and counter for the main hardware constitution.Moreover,the IUFS's working principle,structure design and error analysis are discussed in detail.For its sound reliability and excellent real-time ability,the IUFS is worth popularizing widely in hydropower industry.
What problem does this paper attempt to address?