Bionic Design and Optimization for Monolithic Catalyst Chip

FANG Yu,WANG Lijun,WU Wei,LI Xi
DOI: https://doi.org/10.3969/j.issn.0438-1157.2012.08.012
2012-01-01
Abstract:According to principles and features of biological circulatory system,a novel monolithic catalyst chip with bionic micro-channel network configuration was proposed.It included a multi-stage and multi-function network with separated inflow and outflow systems.A series of high-resolution CFD simulations and optimizations were performed to investigate the characteristics of the bionic configuration.Compared with conventional fixed-bed catalyst chip,flow resistance was greatly reduced by using bionic micro-channel network at the same residence time.Back-mixing was lowered in the optimal bionic network.Strong robustness was verified for the bionic micro-channel network configuration,which would reduce worse effects induced by uncertain factors,such as short passing or blocking in micro-channel network.This kind of bionic network is an ideal configuration fit for monolithic catalyst chip.
What problem does this paper attempt to address?