Radioactive absorbed doses of ~(131)I labeled anti-hepatoma antibody fragments in human organs

WANG Jing,SHI Chang-bei,ZHANG Qing,汪静,施常备,张庆,王喜青,王云雅,李国权,邓敬兰,陈志南
DOI: https://doi.org/10.3760/cma.j.issn.2095-2848.2007.01.011
2007-01-01
Abstract:Objective To calculate the radioactive absorbed dose of ~(131)I labeled anti-hepatoma anti- body fragments[HAb18F(ab)_2]in viscera.Methods The ~(131)I-HAb18F(ab)_2 were intravenous injection to two volunteers.The blood samples were taken at 5 min,30 min,2 h,4 h,8 h,24 b,2 d,3 d,4 d,6 d and 10 d after administration of ~(131)I-HAblSF(ab)_(2).The SPECT imaging was preformed at 3 h,24 h,2 d,4 d, 8 d and 16 d after administration of ~9131)I-HAb18F(ab)_(2).The radioactive concentration in blood samples and the counts of region of interest(ROI)were measured.The drug's effective half life and the absorbed dose in main organs were calculated with Medical Internal Radiation Dose(MIRD).Results The drug's effec- tive half life in main organs ranged from 1.8 to 6.4 d.The absorbed dose was from 28.5 to 3 Gy with high- est at thyroid.Conclusions The way of calculation on absorbed dose is convenient and reliable.The criti- cal organ is thyroid.