Intracellular and extracellular superparamagnetic iron oxides:Signal intensity patterns on MR imaging

Yang Hua,Zhang Xiao-ming,Shao Yang,Jiang Hong,Zeng Nan-lin
2008-01-01
Abstract:BACKGROUND:There are significant differences in the impact of superparamagnetic iron oxide(SPIO) as magnetic resonance(MR) contrast agent to relaxation rate.OBJECTIVE:To explore whether there are differences in the influence of intracellular and extracellular SPIO on the patterns of MR signal intensity,and to determine the optimal protocol of magnetic resonance imaging.DESIGN,TIME AND SETTING:Comparative observation and cell imaging trial.The experiment was performed in Imaging Research Institute and Department of Immunology of North Sichuan Medical College Hospital from June 2006 to January 2007.MATERIALS:Resovist(SHU555A) SPIO was graciously provided by(Schering AG,Germany).Rat bone marrow stromal stem cells were labeled with iron oxide(iron mass concentration 0,4.2,8.4,21,42,and 84 mg/L) and polylysine.METHODS:MR imaging was performed on the Eppendoff tubes filled with SPIO of different concentrations using GE Signa EX-CITE 1.5T MR scanner.MAIN OUTCOME MEASURES:Signal change rules of SPIO on different MR sequences;different influences of intracellular and extracellular SPIO on the patterns of MR signal intensity.RESULTS:Extracellular patterns:The signal intensity of the Eppendoff tubes increased first and then decreased following the in-creasing concentrations of SPIO on T1 weighted image(T1WI),while the signal intensity decreased on T2 weighted images(T2WI).The changes of signal intensity on T1WI and T2WI were more significant than on T2WI,especially on T2WI(P < 0.05).Intracellu-lar patterns:The signal intensity of the culture medium increased following the iron concentration increasing.There were no signifi-cant differences in signal intensity on fast spin echo T1WI when iron concentration ≤ 21 mg/L,while when iron concentration was 42 and 84 mg/L,the signal intensity was significantly increased compared to the control group(P < 0.05).The signal intensity on fast spoiled gradient recalled echo T1WI was significantly higher than the control group when iron concentration was > 8.4 mg/L(P < 0.05).When iron concentration was 4.2 mg/L,the signal intensity on fast spin echo T2WI and gradient recalled echo T2WI were remarkably decreased compared to the control group(P < 0.05),especially on gradient recalled echo T2WI(P < 0.05).CONCLUSION:The relaxation rate in intracellular SPIO is different from in extracellular SPIO.T2 weighted images are sensitive and specific sequences for detecting SPIO.
What problem does this paper attempt to address?