The Local Bearing Capacity on the Top of Steel Column Series Test

Yi LIU,Gen-shu TONG
DOI: https://doi.org/10.3969/j.issn.1007-9467.2008.11.008
2008-01-01
Abstract:This paper describes the acdident survey about the collapsing of the No.2 electric precipitator steel frame of No. 1 300 000 kW generator of a certain power plant in Hubei Province. A series test was carried out on the local bearing capacity for two tops of steel column. to analysis the cause of a large concave deformation happened on the top of steel column.The actual bearing capacity and the actual damage pattern were studied.