Experiment of ceramic microfiltration membrane cleaning by ultrasonic method

Wu Xian,Wu Tian,Liang Peng,Lv Yuzheng
DOI: https://doi.org/10.3969/j.issn.1673-9353.2012.02.006
2012-01-01
Abstract:The ultrasonic method was adopted to clean the ceramic microfiltration membrane,which had a pore size of 0.2 μm and was polluted seriously.The results showed that infiltration flux recovery rate of single membrane could reach 18.0% when the ultrasonic frequency was 20 kHz,the power was 2 000 W,the ultrasonic cleaning time was 35 min and cleaning solution temperature was 40 ℃.The increased rate of membrane infiltration flux could reach 250.0%.It indicated that the ultrasonic method had satisfied cleaning effect for polluted ceramic microfiltration membrane.
What problem does this paper attempt to address?