Study on Treatment of Low-Turbidity and Low-Temperature Beidu River Raw Water Using Composite Coagulants of Polydimethyldiallylammonium Chloride
Yue-jun ZHANG,Xiao-xiao LI,Xiao-lei ZHAO,Dong-kai YIN,Xiao-li WU,Gong-jian SU
DOI: https://doi.org/10.3969/j.issn.1671-7147.2010.03.018
2010-01-01
Abstract:A series of composite coagulants were prepared using polyaluminum chloride(PAC),polyferric sulfate(PFS) or aluminum sulfate(AS) with polydimethyldiallylammonium chloride(PDM) of different molecular weight as raw materials.The enhanced coagulation processes of low-turbidity and low-temperature Beidu raw water by using these composite coagulants were reported in this paper.Jar tests were used to study the influences of the inorganic coagulant sorts,the mass percent of PDM in composite coagulants to the efficiency of turbidity removal.The results indicated that for the winter Beidu raw water of 8~13 ℃ and 6~13 NTU,the dosage of 6.0,9.0,8.5 mg/L were necessary to AS,PFS and PAC,respectively when residual turbidity of 2 NTU was achieved after the treatment.PDM as coagulant aid improved the efficiency turbidity removal remarkably,composite coagulants AS/PDM,PAC/PDM and PFS/PDM could decrease their corresponding inorganic coagulants dose by 8%~20%,12%~40% and 11%~27%,respectively.When residual turbidity of 1 NTU was required,composite coagulants AS/PDM,PAC/PDM and PFS/PDM could decrease the inorganic coagulants dose by 10%~26%,16%~40% and 11.5%~27%,respectively.Therefore,the efficiency turbidity removal and precipitating performance of composite coagulants were remarkable and the higher mass percent and intrinsic viscosity of PDM in composite coagulants,the higher efficiency of composite coagulants.