Determination of Cefetamet Pivoxil in Human Urine and Serum Using Flow Injection Chemiluminescence Procedure

Xiaodong Shao,Xin Li,Bei Liu,Zhenghua Song
DOI: https://doi.org/10.1134/s1061934809010146
IF: 1.237
2009-01-01
Journal of Analytical Chemistry
Abstract:A sensitive chemiluminescence method based on enhancing the effect of cefetamet pivoxil on the chemiluminescent reaction between luminol and dissolved oxygen in a flow injection system was proposed for the determination of cefetamet pivoxil. The increment of the chemiluminescence intensity was proportional to the concentration of cefetamet pivoxil, which yields a calibration graph that is linear over the concentration from 0.4 to 100.0 ng/mL ( r 2 = 0.991) with the detection limit of 0.1 ng/mL (3σ). At a flow rate of 2.0 mL/min complete determination of cefetamet pivoxil, including sampling and washing, could be accomplished in 40 s with the RSD of less than 0.03 ( n = 5). The proposed method was applied successfully to the determination of cefetamet pivoxil in human urine and human serum.
What problem does this paper attempt to address?