Contrast Sensitivity of Aspheric Intraocular after Phacoe Mulsification

Zhen-Ping Huang,Ren-Feng Xu,Yong Wu
DOI: https://doi.org/10.3321/j.issn:0469-5097.2007.05.004
2007-01-01
Abstract:Contrast sensitivity is a new technique, which measures the discrimination capacity of the human eye to an object under low contrast conditions. It is more acute and more complete in reflecting visual function than the Snellen chart, which is used to test the discrimination under high contrast conditions.Our purpose is to compare the effect of an aspheric intraocular lens (Tecnis Z9001) with those of conventional spherical intraocular lens (AR40e IOL) on functional visual performance. Sixty eyes after phacoe mulsification with IOL implantation and 30 eyes of age-matched healthy persons. All of these people with ocular pathology other than cataract or other diseases known to affect contrast sensitivity are excluded.All of these people were 50~80 years old. Corrected visions all are over 20/30. The contrast sensitivity function was measured with CSV-1000E Vision Testing Instrument (provided by Vector Vision Company) in 3 months after surgery. After surgery the patients' contrast sensitivities were better than preoperation. The Tecnis Z9001 intraocular lens provided statistically significantly better contrast sensitivity at 6, 12, 18 cycles per degree. The use of a modified prolate intraocular lens during cataract surgery has the potential to improve contrast sensitivity, which designed to partially compensate the average spherical aberration of the cornea.
What problem does this paper attempt to address?