Computation of integrated effective emissivity of isothermal cavities

DUAN Yuan-yuan,LIU Dong,WANG Jing-hui,YANG Zhen
DOI: https://doi.org/10.3969/j.issn.1671-8097.2012.02.006
2012-01-01
Journal of Thermal Science and Technology
Abstract:Computation of the integrated effective emissivity of cavities is central to blackbody design.A method to calculate the integrated effective emissivity of an isothermal axisymmetric cavity based on the finite element analysis was developed in this work.The average relative deviation of results between this method and the Monte Carlo method is 0.000 9,which shows the high accuracy of the present method.Furthermore,the integrated effective emissivity of an isothermal non-axisymmetric cavity was calculated.The average relative deviation is 0.000 5,which shows that the method is also precise in calculating the integrated effective emissivity of isothermal non-axisymmetric cavities.
What problem does this paper attempt to address?