The Comparative Study of Diffusion-Weighted MR Imaging with Modified Sensitivity Encoding Technique for Small Hepatocellular Carcinoma Lesions

XU Peng-ju,YAN Fu-hua,WANG Jian-hua,ZHOU Mei-ling,CHEN Cai-zhong,LIN Jiang,SHEN Ji-zhang,LI Ren-chen,ZHANG Shu-jie,ZHANG Li-jun
DOI: https://doi.org/10.3760/j.issn:1005-1201.2007.01.003
2007-01-01
Abstract:Objective To prospectively evaluate whether DWI with mSENSE(mSENSE-DW1)can help to improve image quality and affect the calculation of lesion's ADC,compared with DWI with conventional phase encoding(conventional DWI)in patients with small HCC lesions.Methods Thirty-two patients with 47 small HCC lesions underwent single-shot spin-echo echo-planar.(SE-EPI)DWI with conventional phase encoding and mSENSE.Three b values of 300,500 and 800 s/mm~2 were used.Image quality and CNR between conventional DWI and mSENSE-DWI group were compared with different b value. Lesion's ADC were also calculated and compared.Matched-pairs Wilcoxon signed rank test and Friedman test were used to test statistical significance.Results The image quality was assessed with a five-point scale.For conventional DWI group,image quality score of 2 was assigned in 5 cases,score of 3 in 24 cases, score of 4 in remaining 3 eases with b=300 s/mm~2,score of 2 in 9 eases,score of 3 in 22 cases,score of 4 in remainingl cases with b=500 s/mm~2,score of 1 in 2 cases,score of 2 in 24 cases,score of 3 in remaining 6 cases with b=800 s/mm~2.For mSENSE-DWI group,image quality score of 3 was assigned in 4 cases,score of 4 in 25 cases,score of 5 in 3 eases with b=300 s/mm~2,score of 3 in 10 cases,score of 4 in 20 cases,score of 5 in remaining 2 cases with b=500 s/mm~2,score of 2 in 7 cases,score of 3 in 23 eases, score of 4 in remaining 2 cases with b=800 s/mm~2.Higher image quality scores were achieved at mSENSE- DWI group than conventional DWI group(Z=-5.578,-5.488,-4.796 respectively,P0.01)with the sameb value.The lesion's median ADC value was respectively(1.578×10~(-3)),(1.390×10~(-3)), (1.173×10~(-3))mm~2/s for b=300,500,800 s/mm~2 in conventional DWI group and(1.381×10~(-3)), (1.242×10~(-3)),(1.136×10~(-3))mm~2/s in mSENSE-DWI group.There was no significant difference in the lesion's ADC between mSENSE-DWI group and conventional DWI group with high b value(500 and 800 s/mm~2,Z=-0.873,-0.862;P=0.383,0.388,respectively).Conclusion Higher quality images can be achieved in liver DWI with mSENSE without compromising small HCC lesion's ADC calculation.
What problem does this paper attempt to address?