Leakage Detection of Underground Pressureless Industrial Waste Water Pipeline Using GPR、electrical and SP Method

GUO Xiu-jan,MENG Qing-sheng,WANG ji-cheng,JIA Yong-gang,GUO Jian
DOI: https://doi.org/10.3969/j.issn.1004-2903.2007.01.041
2007-01-01
Abstract:The physical properties of soil will vary when it has been contaminated by waste water with oil from the leakage position of pipeline.On the anlysis of this variation,we surveyed the contaminated area using HDR method,Spontaneous Potential method,and GPR method,in order to detect the leakage positions of Underground Industrial Waste Water Pipeline.The analysis of drilling samples from contaminated area indicates that the invasion of sewage with oil will cause the increase of resistivity of clay,and the more the amount of invasion,the higher the resistivity.At the same time,the abnormal patters in HDR profile shows high resistivity;however,the characteristic show low potential in the corresponding Spontaneous Potential profile,and low frequency and high amplitude in GPR profiles.According to the distributive characteristic of abnormal,we can determine the position of leakage spot.The survey result confirmed that the geophysics method is feasible in detecting this kind of industrial sewage pollution problem.