Determination of Fenticonazole Nitrate and Its Related Substances by RP-HPLC

崔家华,邹巧根,冯振斌,张尊建
DOI: https://doi.org/10.3969/j.issn.1001-5094.2010.04.005
2010-01-01
Abstract:Objective:To establish a RP-HPLC method for the determination of fenticonazole nitrate and its related substances.Methods:Discovery C18 column (250 mm×4.6 mm,5 μm)was used with acetonitrile-20 mmol ·L-1 ammonium acetate (70∶30) as mobile phase at a detection wavelength of 229 nm,a flow rate of 1.0 mL ·min-1 and a injection volume of 20 μL.Results:A good resolution between fenticonazole and 5 known impurities was obtained.The linear range of fenticonazole nitrate was 10.3-257.0 mg ·L-1 (r= 0.999 7) and the detection limit was 0.1 ng (S/N=3).Conclusion:The method is simple,accurate and reliable for the quality control of fenticonazole nitrate and its preparations.
What problem does this paper attempt to address?