Abstract:Novel structure and technique are proposed for a polymer directional coupler electro-optic switch with coplanar electrodes and rib waveguides.The electric field is analyzed using conformal transforming method and image method.To get the minimum loss and switching voltage,the electrode parameters are optimized.To realize normal switching function,the switching voltage shift is discussed.Optimization results show the core width,core thickness and rib height are 4.0 μm,1.5 μm and 0.5 μm,respectively;the electrode thickness,width and gap are 0.15 μm,3.0 μm and 3.5 μm,respectively;the coupling length is 3 082 μm,coupling gap is 3.0 μm,and switching voltage is 5.43 V;the insertion loss and crosstalk are less than 0.60 dB and-30 dB,respectively,within the applied voltage range of 5.28~5.59 V.Compared with the simulation results of Beam Propagation Method,this optimized method possesses a high accuracy and presents meaningful instructions for the fabrication of such devices.