Diffusion and transformation of PCDD/Fs of municipal waste incineration plant by using AERMOD model

LI Yu-ting,JIN Yi-ying,LIU Fu-qiang
DOI: https://doi.org/10.3969/j.issn.1000-6923.2013.06.004
2013-01-01
Abstract:In this paper,we predicted the diffusion and transformation of polychlorinated dibenzo-p-dioxins and furans(PCDD/Fs) near one municipal solid wastes incineration plant by using U.S.EPA’S AERMOD model.Based on PCDD/Fs special characteristic with approximately 90%-100% particle-bound in the normal atmospheric temperature,TSP and PM10 were regarded as the transit particle carrier of PCDD/Fs.The results showed that 100% and 80% gas-particle partition setting exerted little influence on the PCDD/Fs air diffusion concentration and migration distance,on the contrary TSP and PM10 particle size distribution significantly affected the evaluated PCDD/Fs concentration.The observed PCDD/Fs concentration was 0.23-1.66 pg I-TEQ/m3,while the predicted concentration of TSP and PM10transit particle carrier were 0.13-1.81 pg I-TEQ/m3 and 0.15-1.68 pg I-TEQ/m3,respectively.The average total uncertainties of the two parameters were 24.31% and 12.43% respectively.The relative difference ratio of the predicted and observed PCDD/Fs air concentration was 0.01-0.89.And the predicted result of PM10 was more related to the observed result than TSP’s.
What problem does this paper attempt to address?