Abstract:Objective To evaluate the clinical application and mid-term result of Gore-Tex suture as an artificial chordae in mitral anterior leaflet valvuloplasty. Methods 38 patients with the anterior leaflet received surgery. The data of the cardiac function (EF), the diameter of left ventricular and left atria and the degree of mitral regurgitation were analyzed before and after operation. Results The degree of mitral regurgitation decreased significantly after operation. The mean degree of pre-operation mitral regurgitation was (3.76±0.43) +, and after surgery was (1.08±0.99)+,P0.05. The diameter of left ventricular and left atria reduced postoperatively. The postoperative cardiac function improved significantly. EF increased from 0.58±0.08 preoperatively to 0.64±0.06 postoperatively (P0.05). Conclusion The Gore-tex suture as an artificial chordae is a safe and effective technique in mitral anterior leaflet valvuloplasty.