Flow-Injection Biosensor System for in Vivo Analysis of Biomolecules in the Extracellular Space of Brain
Tao Yao
2004-01-01
Abstract:The in vivo monitoring of the concentration changes of biomolecules at a variety of sites of the living systems including blood stream, subcutaneous tissue, muscle, internal organs, and brain, has been desired for the pharmacological, clinical, and biological studies. The most general approach to achieve such goals was the use of implanted biosensors, but it was limited because of the variations in sensitivity during the prolonged in vivo monitoring. Recently, microdialysis has been used as a sampling technique for in vivo analysis. This article reviews novel flow-injection biosensor systems which make possible on-line monitoring of glucose metabolism and pharmacological behavior of neurotransmitters in the extracellular space of brain. This approach was developed by coupling microdialysate sampling to the biosensor system using a flow-injection interface. The advances in these researches are reviewed with the results obtained in our recent works. element Microdialysis is a sampling technique for in vivo analysis (l) 2.1. On-line amperometric assay of glucose, Lglutamate, and and has successfully been applied in pharmacological and acetylcholine using immobilized enzyme reactors (14) biological studies of biomolecules in dialysate. In many cases, Here, we describe an on-line amperometric monitoring system however, the dialysate was collected and usually assayed by of glucose, L-glutamate, and acetylcholine. These analytes are not liquid chromatography. detectable by direct electrochemical oxidation. Therefore, we The use of miniaturized biosensors was the most simple chose to use the glucose oxidase (GOD), L-glutamate oxidase approach for the in vivo monitoring, but it was limited because of (GlOD), and acetylcholine esterase (ACE) + choline oxidase the variations in sensitivity during the prolonged in vivo (ChO), to convert each of these analytes to hydrogen peroxide monitoring. In recent years, sensor systems combined which can be detected amperometrically, according to microdialysis sampling have been developed for in vivo analysis /3 -D-glucae + O2 gluconolactone + &02, and continuous monitoring of concentration changes of L-glutamate + O2 2-0xoglutarate + NH3 + H202, and biomolecules in blood (2), subcutaneous tissue (3), and brain (4). acetylcholine + O2 + 2 bo-betaine + acetate + 2 HA. For such researches, some miniaturized enzyme-based Each of the enzymes was loaded or coloaded onto reactor (PEFE amperometric biosensors have been proposed as specific coil; 20 mm X 0.5 mm i.d) packed with aminopropyl-CPG using detectors for the in vivo monitoring of glucose (3, 5-71, L- glutaraldehyde as a cross-linking agent The microdialysis system glutamate (8-101, acetylcholine(ll), and L-lactate (3, 121. A used in this work is outlined in Fig. 1. similar attempt was also achieved by using an enzyme reactor as . The apparatus consisted of a two-channel microsyringe pump, a recognition element of a particular analyte in dialysate, e.g., potentiostat, and a strip chart recorder. Each of the immobilized glucose (13). enzyme reactors was positioned after a microdialysis probe Glucose is a main nutrient in the brain, while L-lactate and shown schematically in Fig. 2 and in front of a poly(l,2- pyruvate are formed from glucose in an actively glycolyzing diaminobenzene) film-coated platinum electrode. A constant system, and are of interest in metabolic disorders. Also, L- potential (+ 0.6 V vs. AgIAgCl) was applied to the polymer film- glutamate and acetylcholine are the most important excitatory coated electrode and the current was recorded. The Ringer's neurotransmitters in the brain. Therefore, the in vivo monitoring of concentration changes in such analytes that take place rapidly in brain cells has been especially desired in the research field of brain chemistry. This article reviews the in vivo flow-injection biosensor systems with an on-line microdialysis sampling which make possible the specific detection of a single analyte or the simultaneous monitoring of plural analytes in brain. This approach has been developed by coupling microdialysis sampling Fig. 1 Schematic diagram of microdialysis system with to the biosensor system using a flow-injection interface. The immobilized enzyme reactor. A: two-channel microsyringe pump, advances in these researches are reviewed with the results B: microdialysis probe, C: sample, D immobilized enzyme obtained in our recent works.