Value of harmonic scalpel in endoscopic thyroid surgery

HUANG Xiaoming,XU Geng,ZHENG Yiqing,CAI Xiang,ZENG Liang,LIU Wei,XU Yaodong,ZHANG Zhigang
DOI: https://doi.org/10.3969/j.issn.1672-7002.2007.06.002
2007-01-01
Abstract:OBJECTIVE To evaluate the value of harmonic scalpel in endoscopic thyroid surgery.METHODS Endoscopic thyroid surgeries through a small incision in sternal notch were performed in 35 cases with thyroid neoplasms from Sep.2002 to Apr.2005 using titanium clamp or harmonic scalpel.RESULTS There were no significant difference on tumor diameter and the age of the patients(P>0.05) among harmonic scalpel group,titanium clamp group and conventional group.The operation time of titanium clamp group was longer than that of harmonic scalpel group or conventional group(P value was 0.003 and 0.001 respectively).There were no difference on operation time between harmonic scalpel group and conventional group(P>0.05).The blood loss in harmonic scalpel group was less than that in titanium clamp group or conventional group(P=0.001).CONCLUSION Harmonic scalpel is a new type of surgical instrument and is suitable for endoscopic thyroid surgery.It is worth of recommending that harmonic scalpel can not only increase safety of surgery and reduce blood loss,but also decrease the difficulty of operation and shorten the operation time.