Treatment of Concentrated Leachate from RO System Using Coagulation, Ammonia Stripping and Fenton Oxidation Processes

万小娇,柴晓利,牛静,赵由才
DOI: https://doi.org/10.3969/j.issn.0517-6611.2011.31.112
2011-01-01
Abstract:[Objective]The research aimed to study the control of concentrated leachate with method of coagulation,ammonia stripping and Fenton oxidation processes.[Method]A treatment process for the concentrated landfill leachate from a reverse osmosis equipment using coagulation,ammonia stripping and Fenton oxidation was developed.The effects of the composite coagulants,ammonia stripping temperature,pH,quantity of flow air,H2O2 and Fe2+ concentrations on COD and NH3-N removals were investigated.[Result]The results showed that the optimum efficiency of coagulation and ammonia stripping could be achieved under the profiles of 6 g/L MgO and 2 g/L Ca(OH)2 by agitating for 24 h followed by blowing air at the speed of 6 L/(min·L) for 4.5-5.0 h at pH of 11.0-11.5.The optimistic conditions of orthogonal tests were H2O2 concentration 750 mmol/L,Fe2+ concentration 28 mmol/L,reaction time 45 min,pH 3.COD and NH3-N removal rates were 93.4% and 95.7% through the whole process.[Conclusion]This research indicated that the control of concentrated leachate with method of coagulation,ammonia stripping and Fenton oxidation processes was ideal and should be studied for next step.
What problem does this paper attempt to address?