Abstract:Objective To cope with the newest tissue weighting factors recommended by ICRP and develop a set of software for convenient estimation of the organ dose and effective dose of patients inclinical nuclear medicine.Methods Relevant electronic databases were built based on the dose conversion coefficients recommended byICRP.The organ doses were estimated using the S value method,and the effective doses were evaluated by using the newest tissue weighting factors.The software was developed by using C + + programming language.Results The software can be used to estimate the absorbed doses of 27 organs/tissues and the effective doses for patients in clinical nuclear medicine applications involving a total of 47 kinds of radionuclides and 268 chemical compounds.The variance of estimated effective dose for patients undergoing diagnostics with 99mTc、18F and 131I are 20%,8% and 32% by using different versions of tissue weight factors.Conclusions The database established in this study contains a large number of radionuclides and their compounds.It can be applied for simple estimations of the organ dose and effective dose of patients in clinical nuclear medicine procedures.