Thermal analysis of HTS air-core transformer used in voltage compensation type active SFCL

M. Song,Y. Tang,J. Li,Y. Zhou,L. Chen,L. Ren
DOI: https://doi.org/10.1016/j.physc.2010.05.182
2010-01-01
Abstract:The three-phase voltage compensation type active superconducting fault current limiter (SFCL) is composed of three HTS air-core transformers and a three-phase four-wire Pulse Width Modulation (PWM) converter. The primary winding of the each phase HTS air-core transformer is in series with the main system, and the second winding is connected with the PWM converter. The single-phase conduction-cooled FITS air-core transformer is consisting of four double-pancakes wound by the Bi2223/Ag tape. In this paper, according to the electromagnetic analysis on the single-phase FITS air-core transformer, its AC loss corresponding to different operation modes is calculated. Furthermore, the thermal behaviors are studied by the time-stepping numerical simulations. On the basis of the simulation results, the related problems with the HTS air-core transformer's thermal stability are discussed. (C) 2010 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?