Determination of the Faropenem Concentration in Human Plasma by LC-MS/MS

GUO Qing-ping,ZHANG Quan-ying,SHI Ai-ming,HUA Wen-yan,ZHU Yi-fang,WANG Meng,PAN Jie
2010-01-01
Abstract:Objective To establish a quantified analytical method for determination of faropenem in human plasma by LC-MS/MS.Method The LC-MS/MS conditions adopted were:ZORBAX Eclipse Plus(100 mm×2.1 mm,3.5 μm).The mobile phase consisted of acetonitrile-5m mol/L ammonium acetate (35:65).The flow rate was 0.3 ml/min.Wenlafaxine was used as internal standard.Results In human plasma,the standard curve was linear from 0.1~20 μg/ml,Y=0.270 0 c + 0.002 42(r=0.995 5,n=8).The lower limit of quantification of faropenem was 0.1μg/ml.The RSD of within-day was less than 5.4%,the RSD of between-day was less than 7.9%,and the method recovery rate was 99.0%~113%.Conclusion The assay is simple to operate,accurate,reliable and short analysis time,and makes it suitable for the clinical pharmacokinetics and bioequivalence studies.
What problem does this paper attempt to address?