Improving ammonia nitrogen removal and recovery by BMED stack optimization: The effect of ion exchange membrane thickness

Jeong Keun Kim,Hong Gun Kim,Lee Ku Kwac,Namjo Jeong,Kyo Sik Hwang
DOI: https://doi.org/10.1016/j.ces.2024.120203
IF: 4.7
2024-05-12
Chemical Engineering Science
Abstract:Bipolar membrane electrodialysis (BMED) has emerged as an efficient and promising technology for the removal and recovery of ammonia nitrogen. Despite its potential, the optimization of BMED systems for enhanced performance and energy efficiency remains a critical challenge, particularly in the context of varying ion exchange membrane (IEM) thicknesses. Membranes with a thickness of 250 μm have higher ion selectivity than commercial membranes with a thickness of 80–250 μm and are suitable for processes that demand high purity. This study investigates the effect of IEM thickness ranging from 16–400 μm on BMED performance for ammonia nitrogen removal and recovery, and energy consumption. The BMED configuration comprising five cell triplets consisting of a cation exchange membrane, bipolar membrane, and anion exchange membrane was employed. The thickness of IEMs was divided into three categories: 16–17 μm (PCEM/ PAEM), 100–150 μm (CD100/AD100, InnoSep-C/InnoSep-A), and 380–400 μm (MC-3470/MA-3475). In membranes with a thickness of 100–150 μm, the ammonia nitrogen removal was exceptionally high at 99.2 %, with a recovery of 98.7 % (CD100/AD100: 100 μm) at a current density of 80 mA/cm 2 , and the system exhibited low specific energy consumption (SEC) of 8.87 kWh/kg-N (InnoSep-C/InnoSep-A: 150 μm) at a current density of 20 mA/cm 2 . However, when using the thinnest IEMs (PCEM: 16 μm, PAEM: 17 μm), an increase in total ammonia nitrogen loss (10.21–22.01 %) led to a reduction in ammonia nitrogen recovery. Conversely, when using the thickest IEMs (MC-3470: 380 μm, MA-3475: 400 μm), the SEC was extremely high (30.98–126.67 kWh/kg-N), making them unsuitable for the BMED process for ammonia nitrogen removal and recovery. Based on these experimental results, it is suggested to use an optimal thickness of IEM within the range of 80–250 μm in the BMED systems to achieve a balanced performance, maximizing ammonia nitrogen removal and recovery while minimizing the SEC. Consequently, the present study provides a comprehensive understanding of the effects of the IEM thicknesses on the BMED systems and could offer a practical perspective for optimizing the BMED stack with respect to improving the removal and recovery rate of ammonia nitrogen and reducing the energy consumption.
engineering, chemical
What problem does this paper attempt to address?