Assessment of Wearable Cooling and Dehumidifying System Used under Personal Protective Clothing through Human Subject Testing

Yiying Zhou,Lun Lou,Jintu Fan
DOI: https://doi.org/10.3390/pr12061126
IF: 3.5
2024-05-31
Processes
Abstract:Healthcare professionals wearing personal protective equipment (PPE) during outbreaks often experience heat strain and discomfort, which can negatively impact their work performance and well-being. This study aimed to evaluate the physiological and psychological effects of a newly designed wearable cooling and dehumidifying system (WCDS) on healthcare workers wearing PPE via a 60 min treadmill walking test. Core temperature, mean skin temperature, heart rate, and subjective assessments of thermal sensation, wetness sensation, and thermal comfort were measured throughout the test. Additionally, ratings of wearing comfort and movement comfort were recorded during a wearing trial. The results showed that the WCDS significantly reduced core temperature, improved thermal sensation, and reduced wetness sensation compared to the non-cooling condition. The microclimatic temperature within the PPE was significantly lower in the cooling condition, indicating the WCDS's ability to reduce heat buildup. The wearing trial results demonstrated general satisfaction with the wearability and comfort of the WCDS across various postures. These findings contribute to the development of enhanced PPE designs and the improvement in working conditions for healthcare professionals on the frontlines during outbreaks.
engineering, chemical
What problem does this paper attempt to address?