Effects of reflux hole of volute on the performance of self-priming pump

L. Xia
Abstract:Reflux hole helps self-priming pumps to improve self-priming performance when the reflux liquid flows into volute.Its position and area have a great influence on the self-priming capability and efficiency of the pump.The internal flow field of the self-priming pump was numerically simulated with the CFD method,to study the flow characteristics nearby the reflux hole and analyze the impact of the position and area of the reflux hole on the internal flow as well as the pump performance.The simulation results showed that the tendencies of simulation results matched with the experimental data.When the pump was operated at its design point,the reflux flow rate increased with the area of the reflux hole and consequently the self-priming capability was improved without suppressing the pump performance.When the flow rate was larger than the nominal flow rate,the increase of the area of the reflux hole leaded to the leakage that flowed from the volute to liquid storage chamber,which caused greater volume loss.The position of reflux hole had influence on the pressure difference between the inside and outsider of the volute.The position of reflux hole was closer to the tongue,the pressure difference between the volute and the liquid separating chamber was bigger.And the leakage flowed from the volute into liquid storage through reflux hole was larger,which reduced the efficiency of the pump.So there is an optimal area and position of reflux hole for a specific self-priming pump.