Experimental Study on Influencing Factors of Self-priming Performance of Inner-recirculation Self-priming Centrifugal Pumps

Cai Zhen-hua
Abstract:Aim at 5 inner recirculation self-priming centrifugal pumps that specific speed are 74~112,adopt 3 different inner-diameter suction pipes and 6 kinds of separation tongue gap,a more overall experimental study on self-priming time under rule height and the max vacuum that can be attained was carry on.Results of the experiment were analyzed synthetically.The results suggest that for inner recirculation self-priming centrifugal pumps,the self-priming time under rule height overall was increasing with the initial air volume inside suction pipes by linear,but the max vacuum have nothing to do with the initial air volume.While separation tongue gap as 1~6 mm,separation tongue gap smaller,self-priming performance more good;the rate flow of the pump is greater,self-priming time to be subjected to influence of separation tongue gap greater.The study have more important meaning to hydraulic design and parts of structure parameters decision of inner recirculation self-priming centrifugal pumps.
Engineering
What problem does this paper attempt to address?