Minimizing energy losses and enhancing performance of Trombe wall systems through partial evacuation of the air gap

Mahmud H. Ali,Mahmood K. Mawlood,Rawand E. Jalal
DOI: https://doi.org/10.1016/j.enbuild.2024.113959
IF: 7.201
2024-02-03
Energy and Buildings
Abstract:Trombe walls serve as passive solar heating systems . However, their effectiveness is hindered by substantial heat loss through the glazing. In response to this challenge, this study suggests a new method that involves a partial evacuation of the air gap between the storage wall and the glazing which is deemed to reduce the convective and conductive heat losses from the gap. An experimental full scale test room with dimensions of 4.0 m x 3.0 m x 2.75 m is constructed in Kirkuk, Iraq and integrated with a Trombe wall. In addition, a numerical simulation method and a computer code is developed to mimic the behavior of the presented system. The accuracy of the numerical approach is validated against experimental data measured under local atmospheric pressure and a vacuum pressure of −0.3 bar gage applied to the air gap of the Trombe wall. Subsequently, the numerical approach is utilized to perform simulations of the undertaken system at different air gap vacuum pressures. Results have shown a decrease in the heat losses and an increase in the efficiency of the system with reduced gap pressure. Further numerical tests have revealed that reducing the gap pressure will have more pronounced effect on the system efficiency when the emissivity of the gap walls is also reduced showing a dominant role played by radiation heat transfer in forming the heat losses. Therefore, numerical simulations are conducted at air gap pressures of 1.0, 0.5 and 0.1 bar and emissivity values of 0.9, 0.5 and 0.1. The combined effect of evacuation and emissivity reduction significantly enhances the efficiency and reduces the heat losses of the system. Notably, the results reveled that partial evacuation of the air gap to 0.1 bar, with the reference emissivity value of 0.9, improves performance and increases system efficiency by approximately 17 %. When emissivity values are reduced to 0.5 and 0.1, efficiency increases by about 26 % and 36 %, respectively. However, the most substantial efficiency gain is achieved by reducing both gap pressure and emissivity to 0.1 bars and 0.1, respectively, leading to a remarkable 170 % increase compared to the reference state of 1.0 bar gage pressure and emissivity of 0.9. Consequently, a rise in the average room temperature of 3.4 °C is also observed. Furthermore, the outcomes generated by the numerical approach for a number of climatic conditions of winter season are utilized to formulate an empirical equation for estimation of the system performance at different conditions. The empirical equation is derived and tested by applying the artificial neural networking technique and its simulated performance parameters are found to agree very well with the target performance variable.
energy & fuels,construction & building technology,engineering, civil
What problem does this paper attempt to address?