Structural performance of CFRP-confined RC columns under earthquake-induced fire

Ju-Hyung Kim,Yail J. Kim
DOI: https://doi.org/10.1016/j.engstruct.2024.118097
IF: 5.582
2024-05-01
Engineering Structures
Abstract:This paper presents numerical investigations into the performance and risk of a reinforced concrete column confined with carbon fiber reinforced polymer (CFRP) sheets alongside an insulation layer when subjected to earthquake-induced fire. For a comparative assessment, the response of an unconfined control column is predicted as well. A five-story benchmark building is selected and the likelihood of fire ignition is simulated under 50 ground motions. Afterward, employing stochastic approaches, the moment capacity and uncertainty of the unconfined and confined columns (C0 and CONF, respectively) are computed within a thermal exposure period of 3 h. The maximum acceleration of 0.28 g obtained from the benchmark building frame indicates the possible occurrence of a fire without significant structural damage. The thermal distress lowers the median capacity of the C0 and CONF columns by 19% and 5%, respectively, and remarkably raises the uncertainty of C0, which differs from the case of CONF. Parametric studies reveal that, during the 3-hour fire loading, the functionality of the columns is dominated by the compressive strength of concrete and a prominent enhancement is noticed for the confined column in terms of preserving functionality against its unconfined counterpart. The insulation layer plays a crucial role in controlling the efficacy of the CFRP system. As far as reliability and hazard are concerned, the CONF column outperforms the C0 column.
engineering, civil
What problem does this paper attempt to address?