Highly sensitive ECL detection of miRNA based on self-generated coreactant and target-induced catalyzed hairpin assembly
Xinli Wang,Hongyan Liu,Shaoqiang Zhang,Zhongcui Jing,Changkai Zhang,Songxia Yan,Hong Zhou,Haiyan Wang
DOI: https://doi.org/10.1016/j.aca.2024.343103
2024-10-02
Abstract:Background: Recently, various techniques have been developed to accurately and sensitively detect tumor biomarkers for the early diagnosis and effective therapy of cancer. The electrochemiluminescence (ECL) method holding outstanding features including high sensitivity, ease of operation, and spatiotemporal controllability exhibited great potential for DNA/RNA detection, immunoassay, cancer cell detection, and environmental analysis. However, a glaring problem of ECL approaches is that the layer-by-layer modification on the electrode leads to poor stability and sensitivity of the sensors. Therefore, new simple and efficient methods for electrode modification which can effectively improve the ECL signal have attracted more and more research interests. Results: Based on the dual amplification strategy of target-induced CHA and nanocomposite probes leading to self-generated co-reactant (H2O2), we proposed a highly sensitive miRNA-ECL detection system. The introduction of the target miRNA-21 triggers the CHA cycle amplification of DNA1 and biotin-modified DNA2, releasing the target miRNA-21 sequence for the target cycle reaction. After the reaction, the newly introduced DNA2 was combined with Au NPs modified with SA and Glucose oxidase (GOD). In the presence of oxygen, glucose was decomposed by GOD to produce H2O2, and then H2O2 was immediately catalyzed by the Hemin/G-quadruplex at the double-stranded end of the CHA product to produce a large amount of O2-•. As a co-reactant of luminol, the ECL signal was significantly enhanced, thereby achieving highly sensitive detection of miRNA-21 content and obtaining a low detection limit of 0.65 fM. The high specificity of the ECL biosensor was also proved by base mismatch. Significance: Compared with other current detection methods, this sensor can achieve quantitative analysis of other target analytes by flexibly changing the probe DNA sequence, and provide a new feasible solution for the detection of tumor-associated markers. Benefiting from the improved sensitivity and selectivity, the proposed biosensing platform is expected to provide a new strategy for biomarkers analysis and outstanding prospect for further clinical application.