High-Entropy Oxide for Highly Efficient Luminol–Dissolved Oxygen Electrochemiluminescence and Biosensing Applications

Fuad Abduro Bushira,Ping Wang,Yongdong Jin
DOI: https://doi.org/10.1021/acs.analchem.1c05005
IF: 7.4
2022-01-31
Analytical Chemistry
Abstract:The luminol–dissolved O2 (DO) electrochemiluminescence (ECL) sensing system has recently gained growing interest; however, the drawback of the ultra-low ECL signal response greatly hinders its potential quantitative applications. In this work, for the first time, we explored the use of high entropy oxide (HEO) comprising five metal ingredients (Ni, Co, Cr, Cu, and Fe), to accelerate the reduction reaction of DO into reactive oxygen species (ROS) for boosting the ECL performance of the luminol–DO system. Benefiting from the existing abundant oxygen vacancies induced by the unique crystal structure of the HEO, DO could be efficiently converted into ROS, thus significantly boosting the performance of the corresponding ECL sensor (with an ∼240-fold signal enhancement in this study). As a proof of concept, under optimal conditions, the developed HEO-involved luminol–DO ECL sensing system was successfully applied for efficient biosensing of dopamine and alkaline phosphatase with a fine linear range from 1 pM to 10 nM and from 0.01 to 100 U/L as well as a low limit of detection of 5.2 pM and 0.008 U/L, respectively.The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acs.analchem.1c05005.Chemicals and materials; materials characterizations; PXRD patterns of the HE-LDH, HEO calcinated at different temperatures, HEO-C and their corresponding SEM images; SEAD pattern of the HEO-900; XPS survey spectra of the HEO-900; O 1s XPS spectra of various HEO; EIS characterizations of the GCE modified by different HEO substrate; typical CVs of the GCE/HEO-900 electrode for ECSA calculation; ECL intensity of various metal oxides in the luminol−O2 (HEO) ECL system; O 1s spectra of the different metal oxides samples tested; SEM images of non-HEO oxides and their corresponding ECL; ECL intensity of the luminol−DO ECL system with HEO-900, before and after post-treatment to remove possible HEO impurity; spectral emission of luminol at different wavelengths; the relationship between ECL intensity with pH value of the system and different initial potentials; phenol quenching mechanism of dopamine luminol−O2; dopamine quenching reaction mechanism with O2•−; optimizing temperature, pNPP concentration, and incubation time for ALP detection; ECL intensity of HEO-900 luminol−DO ECL sensor quenching by ALP with a concentration in the range of 0.01-500 U/L; the elemental compositions of HEO-900 determined by XPS and confirmed by ICP-OES; the elemental composition of different HEO samples determined by XPS; the elemental composition of different lower entropy oxide (LEO) samples determined by XPS; comparison of different methods for the detection of DA and ALP; the recovery results for DA and ALP detection in spiked human serum samples (PDF)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?