Ag–O–Co Interface Modulation-Amplified Luminol Cathodic Electrogenerated Chemiluminescence
Rui Zou,Ruyu Xie,Yage Peng,Weijiang Guan,Yanjun Lin,Chao Lu
DOI: https://doi.org/10.1021/acs.analchem.2c00050
IF: 7.4
2022-03-11
Analytical Chemistry
Abstract:It remains a great challenge to develop effective strategies for improving the weak cathodic electrogenerated chemiluminescence (ECL) of the luminol-dissolved O2 system. Interface modulation between metal and supports is an attractive strategy to improve oxygen reduction reaction (ORR) activity. Therefore, the design of electrocatalysts via interface modulation would provide new opportunities for the ECL amplification involving reactive oxygen species (ROSs). Herein, we have fabricated an Ag single-atom catalyst with an oxygen-bridged interface (Ag–O–Co) through the electrodeposition of Ag on a CoAl layered double hydroxide (LDH) modified indium tin oxide (ITO) electrode (Ags/LDH/ITO). Interestingly, it was found that the cathodic ECL intensity of the luminol-dissolved O2 system at the Ags/LDH/ITO electrode was extraordinarily enhanced in comparison with those at bare ITO and other Ag nanoparticle-based electrodes. The enhanced ECL performances of the Ags/LDH/ITO electrode were attributed to the increasing amounts of ROSs by electrocatalytic ORR in the Ag–O–Co interface. The electron redistribution of Ag and Co bimetallic sites could accelerate electron transfer, promote the adsorption of O2, and sufficiently activate O2 through a four-electron reaction pathway. Finally, the luminol cathodic ECL intensity was greatly improved. Our findings can provide inspiration for revealing the interface effects between metal and supports, and open up a new avenue to improve the luminol cathodic ECL.The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acs.analchem.2c00050.XRD patterns of as-prepared samples; UV–vis absorption spectra of as-prepared samples; HRTEM image of Agnp/LDH; XPS spectra of Al 2p for LDH/ITO, Agnp/LDH/ITO, and Ags/LDH/ITO; optimization of potential scan ranges from −0.8 V to different positive potentials at Ags/LDH/ITO electrode; optimization of potential scan ranges from different negative potentials to 0.8 V at Ags/LDH/ITO electrode; effect of pH on luminol cathodic ECL at Ags/LDH/ITO electrode; ECL stability of Ags/LDH/ITO under 10 continuous CV scans; IECL–time curves for Pt sheet electrode, ITO, LDH/ITO, and Ags/LDH/ITO electrodes; ECL intensities at Ags/LDH/ITO electrode in N2-, air-, and O2-saturated luminol solutions; ECL intensities at Ags/LDH/ITO electrode with the addition of BQ, IPA, or NaN3 as radical scavengers, respectively; Tafel slope curves of Agnp/ITO, Agnp/LDH/ITO, and Ags/LDH/ITO electrodes; EIS spectra of ITO, LDH/ITO, Agnp/ITO, Agnp/LDH/ITO, and Ags/LDH/ITO electrodes; UV spectra of formazan by Agnp/LDH/ITO and Ags/LDH/ITO in KOH/DMSO solutions; LSV curves of Ags/LDH/ITO electrode and Agnp/LDH/ITO electrode in O2-saturated PBS (pH = 7.5) solution at different rotation rates; ECL intensities at Ags/LDH/ITO electrodes with different Ag electrodeposition cycles; peak positions and relative contents of XPS O 1s at Agnp/LDH/ITO and Ags/LDH/ITO; peak positions and Co3+/Co2+ ratios of XPS Co 2p for LDH/ITO, Agnp/LDH/ITO, and Ags/LDH/ITO (PDF)This article has not yet been cited by other publications.
chemistry, analytical